Abstract
An imaging Fourier transform spectrometer operating in the medium infrared () has been used to image two gas sources: a controlled leak at room temperature and the exhaust of a combustion engine. Spectra have been acquired at a resolution of using an extended blackbody as the background. By fitting them with theoretical spectra generated with parameters from the High-Resolution Transmission Molecular Absorption database, quantitative maps of temperature and gas column density (concentration·path product) for the gas plumes have been obtained. Spectra are related to gas plume parameters by means of a radiometric model that takes into account not only gas absorption, but also its emission and the atmospheric absorption, as well as the instrument lineshape function. Measurements for the gas leak show very good agreement between retrieved and nominal values of temperature and column density. This result has direct application to obtain quantitative imaging of exhaust emissions from automobiles and other mobile sources, as shown here with measurements of exhaust gases in a diesel engine.
© 2015 Optical Society of America