Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Gating a channel photomultiplier with a fast high-voltage switch: reduction of afterpulse rates in a laser-induced fluorescence instrument for measurement of atmospheric OH radical concentrations

Not Accessible

Your library or personal account may give you access

Abstract

By employing a commercially available high-voltage switch in a time-gating circuit to drive a channel photomultiplier (CPM), the afterpulse rates are significantly reduced in the time window to collect fluorescence >200  ns after the pulsed laser excitation. The CPM, kept deactivated under normal conditions (normally off), is turned on immediately after the passage of the laser pulse by shifting the voltage applied to the photocathode by 150  V to collect the fluorescence. When the detection system is used as part of a laser-induced fluorescence instrument to measure atmospheric OH radicals with the photon-counting method, the background signal is reduced by more than a factor of 10 as compared with our previous case where a conventional dynode-gated photomultiplier tube (PMT) is used, while the sensitivity toward the fluorescence is almost unchanged. A detection limit as low as 2×105  radicals cm3 or 0.008 parts per trillion by volume is achieved for OH, with an integration time of 1 min and a signal-to-noise ratio of 2, enabling sensitive detection of the important radical in the atmosphere. This system is a superior choice with higher sensitivity and cost effectiveness as compared with the gated PMTs utilizing a microchannel plate as an electron multiplier, and could also be used effectively in light detection and ranging (lidar) instruments, where a delayed scattering signal would be efficiently discriminated from afterpulses.

© 2006 Optical Society of America

Full Article  |  PDF Article
More Like This
Suppression of afterpulsing in photomultipliers by gating the photocathode

Michael P. Bristow
Appl. Opt. 41(24) 4975-4987 (2002)

Signal linearity, gain stability, and gating in photomultipliers: application to differential absorption lidars

Michael P. Bristow, Donald H. Bundy, and Anthony G. Wright
Appl. Opt. 34(21) 4437-4452 (1995)

Method for the reduction of signal-induced noise in photomultiplier tubes

Cynthia K. Williamson and Russell J. De Young
Appl. Opt. 39(12) 1973-1979 (2000)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (5)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (1)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved