Abstract
A detailed description of the design procedure for a new concentrator, RX, and some examples of it’s use are given. The method of design is basically the same as that used in the design of two other concentrators: the RR and the XR [Appl. Opt. 31, 3051 (1992)]. The RX is ideal in two-dimensional geometry. The performance of the rotational RX is good when the average angular spread of the input bundle is small: up to 95% of the power of the input bundle can be transferred to the output bundle (with the assumption of a constant radiance for the rays of the input bundle).