Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Enhanced three-dimensional reconstruction from confocal scanning microscope images. II. Depth discrimination versus signal-to-noise ratio in partially confocal images

Not Accessible

Your library or personal account may give you access

Abstract

The enhanced depth discrimination of a confocal scanning optical microscope is produced by a pinhole aperture placed in front of the detector to reject out-of-focus light. Strictly confocal behavior is impractical because an infinitesimally small aperture would collect very little light and would result in images with a poor signal-to-noise ratio (SNR), while a finite-sized partially confocal aperture provides a better SNR but reduced depth discrimination. Reconstruction algorithms, such as the expectation-maximization algorithm for maximum likelihood, can be applied to partially confocal images in order to achieve better resolution, but because they are sensitive to noise in the data, there is a practical trade-off involved. With a small aperture, fewer iterations of the reconstruction algorithm are necessary to achieve the desired resolution, but the low a priori SNR will result in a noisy reconstruction, at least when no regularization is used. With a larger aperture the a priori SNR is larger but the resolution is lower, and more iterations of the algorithm are necessary to reach the desired resolution; at some point the a posteriori SNR is lower than the a priori value. We present a theoretical analysis of the SNR-to-resolution trade-off partially confocal imaging, and we present two studies that use the expectation-maximization algorithm as a postprocessor; these studies show that a for a given task there is an optimum aperture size, departures from which result in a lower a posteriori SNR.

© 1994 Optical Society of America

Full Article  |  PDF Article
More Like This
Theoretical analysis of a rotating-disk partially confocal scanning microscope

José-Angel Conchello and Jeff W. Lichtman
Appl. Opt. 33(4) 585-596 (1994)

Quantitative comparison of background rejection, signal-to-noise ratio, and resolution in confocal and full-field laser scanning microscopes

D. R. Sandison, D. W. Piston, R. M. Williams, and W. W. Webb
Appl. Opt. 34(19) 3576-3588 (1995)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (13)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (17)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved