Measurements of linear diattenuation and linear retardance spectra with a rotating sample spectropolarimeter

Not Accessible

Your library or personal account may give you access

Abstract

A technique to measure linear diattenuation and retardance spectra of infrared materials in transmission is described. A sample is rotated between two stationary linear polarizers in the sample compartment of a Fourier transform infrared spectrometer. The intensity modulation that results from the rotation of the sample is Fourier analyzed, and the linear diattenuation and linear retardance of the sample are calculated from the Fourier series coefficients for each wavelength. The advantages of this technique include immunity of the measurement to instrumental polarization, to circular diattenuation, and to circular retardance. The rotating sample polarimeter does not require retarders. Compensation for systematic errors from polarizers with diattenuation less than one is included in the data reduction. This technique is useful for the calibration of retarders and polarizers and hence for the bootstrap calibration of more elaborate polarimeters such as Mueller matrix polarimeters. We present as an example of the technique the caliration spectra 3–14 μm of an infrared quasi-achromatic retarder whose fast axis orientation oscillates with wavelength.

© 1993 Optical Society of America

Full Article  |  PDF Article

Corrections

David B. Chenault and Russell A. Chipman, "Measurements of linear diattenuation and linear retardation spectra with a rotating sample spectropolarimeter: erratum," Appl. Opt. 33, 1145-1145 (1994)
https://opg.optica.org/ao/abstract.cfm?uri=ao-33-7-1145

More Like This
Measurement of linear birefringence and diattenuation properties of optical samples using polarimeter and Stokes parameters

Po-Chun Chen, Yu-Lung Lo, Tsung-Chih Yu, Jing-Fung Lin, and Tsung-Tse Yang
Opt. Express 17(18) 15860-15884 (2009)

Mueller matrix dual-rotating retarder polarimeter

Dennis H. Goldstein
Appl. Opt. 31(31) 6676-6683 (1992)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (6)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (11)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved