Abstract
The scaling of laser damage thresholds with irradiated spot size is a well-known effect. When damage is defect dominated, the spot-size scaling can be attributed to the conventional definition of the threshold at the 50% level of damage probability. By redefining the threshold at the 0% level (absolute damage onset), one obtains a result that is spot-size independent. A method is presented here for obtaining the damage onset of optical surfaces subjected to pulsed laser radiation. The method involves weighted least-squares fitting of damage frequency data with a three-parameter distributed ensemble representing inherent defect damage characteristics. Spot-size effects in the data are simulated by a scaling transformation applied to the ensemble before fitting. Direct and inverse transformations are derived for Gaussian and top-hat spatial intensity profiles, and advantages of the latter for testing are pointed out. Three examples of applications to 2.7-μm multilayer coatings are presented, and the general inadequacy of the two-parameter degenerate ensemble is demonstrated. Extraction of defect densities, discrimination of different defect classes, and representation of uncertainty in the onset are discussed.
© 1984 Optical Society of America
Full Article | PDF ArticleMore Like This
Robert M. O’Connell
Appl. Opt. 31(21) 4143-4153 (1992)
Yejia Xu, Luke A. Emmert, and Wolfgang Rudolph
Appl. Opt. 54(22) 6813-6819 (2015)
Karl H. Guenther and Roland G. Menningen
Appl. Opt. 23(21) 3754-3758 (1984)